PYREX  REDLINE Gage Glass            
               
General Application: Tanks, reservoirs, low pressure boilers.        
               
Ends Finish: Diameters greater than or equal to 3/4" with lengths less than or equal to 72" are fire polished. All other  
diameters and lengths are saw cut.            
               
WARNING                
(1) Improper installation or maintenace of tublar glass can cause innediate or delayed glass breakage resulting in bodily injury. To avoid 
breakage observe the  Do's and Do Not's and Use and Care Instructions which are listed in the index, as well as tubular gage
manufacturer's instructions.              
               
(2) If a gage glass breaks, contained substances can be released and glass can be blown out of the unit with great force. Always wear
safety glasses when looking toward a gage or working on a gage glass assembly. Guard against the possibility of fire and explosion.
               
(3) Protect glass from impact, scratches, other surface damage and sudden temperature changes. These can weaken or stress the glass
and lead to breakage.              
               
(4) A good safety practice is to incorporate a protective guard or shield in the gage glass assembly, i.e., a shield between the user
and the gage. Refer to the gage manufacturer's catalog.               
               
(5)Review in detail the Corrosives information which is listed in the index.        
               
(6) Review the disclaimer information which is listed in the index.        
               
(7) Clerical errors may exist in this chart. Please confirm information before relying on the data.    
               
                 Maximum Recommended
                 Working Pressure, psi
          Std.   Temperatures Steam Boiler
  Diameter Diameter   Wall Length Pcs. Per Up To 150 degrees F Service
Diameter Tolerances (+) Tolerances (-) Wall Tolerances (+/-) (Inches) * Case No Corrosion ** Up To 425 degrees F
1/2" O.D. 0.0"  -1/32"  5/64"  + / - 1/64" 8 12 390 300
(.500" O.D.) (.000") (.0313") (.078") (+ / - .0156") 10 12 370 295
          12 12 360 295
* Intermediate lengths are available upon request 14 12 345 290
          16 12 335 285
** See the Corrosives information cited in the index 18 12 325 280
          20 12 310 280
*** Maximum length for steam boiler is 24"   24 12 280 270
          30 12 250 Not Recommended ***
  Please review the Do's and Do Not's before installation cited in the index  36 12 215 Not Recommended ***
          48 12 175 Not Recommended ***
          60 12 135 Not Recommended ***
          72 12 100 Not Recommended ***
5/8" O.D. 0.0"  -1/32" 3/32"  + / - 1/64" 8 12 370 285
(.625" O.D.) (.000") (.0313") (.094") (+ / - .0156") 10 12 345 280
          12 12 335 280
* Intermediate lengths are available upon request 14 12 325 275
          16 12 315 270
** See the Corrosives information cited in the index 18 12 305